在做一个测量架的瞬态分析时,出现以下警告
*** WARNING ***                         CP =     511.109   TIME= 19:37:55
A reference moment value times the tolerance is used by the            
Newton-Raphson method for checking convergence.  The calculated         
reference MOMENT CONVERGENCE VALUE = 0 is less than a threshold.  This  
threshold defaults to 1.0 or is specified as MINREF on the CNVTOL      
command.  Check results carefully.        
求解命令下  

/SOLU

*DIM,TMYA,TABLE,126,8,1

*TREAD,TMYA, TDATSOLID185,TXT,,0

ANTYPE,TRANS

TRNOPT,FULL

OUTRES,ALL,ALL

NLGEOM,OFF

SOLCONTROL,ON

TIMINT,OFF

AUTOTS,ON

BETAD,6E-4

TIME,1E-6

NSUBST,2

KBC,1  

F,TMYA(1,1,1),FY,-19.25,,TMYA(1,8,1),1

F,TMYA(1,1,1),FX,-0.982,,TMYA(1,8,1),1

SOLVE

TIMINT,ON

TIME,0.1

SOLVE

TIMINT,ON

NSUBST,1

*DO,I,2,125

TIME, (I-1)*0.2

FDELE,ALL,ALL

F,TMYA(I,1,1),FY,-19.25,, TMYA(I,8,1),1

SOLVE

*ENDDO

TIME,25
FDELE,ALL,ALL

F,TMYA(126,1,1),FY,-19.25,,TMYA(126,8,1),1

F,TMYA(126,1,1),FX,0.982,,TMYA(126,8,1),1

SOLVE
修改M的收敛准则后还会出现HT的,请问各位大神,我改怎么解啊,我并没有用到HT的,在收敛图里,HT都是0.求大神帮帮忙

ANSYS收敛问题

本帖子中包含更多资源

您需要 登录 才可以下载或查看,没有账号?注册会员

x
您需要登录后才可以回帖 登录 | 注册会员

本版积分规则  | 请遵守晓木虫管理条例,不得违反国家法律法规